Action class for project management.
Parameter | Description |
---|---|
TYPE |
Type of task to be performed: • READPROJECTINFO: Load project information from an XML file into the project. • ToggleSections:If project sections are enabled, temporarily enables/disables whole project for the currently logged-in user. Note: The project must be open. • PUBLISHTODISK: Publishes project to disk. • PUBLISHTOEMAIL: Publishes project to e-mail. • PUBLISHSMARTWIRINGTODISK: Publishes project for EPLAN Smart Wiring to disk. • PUBLISHSMARTWIRINGTOEMAIL: Publishes project for EPLAN Smart Wiring to e-mail. • CREATESNAPSHOTCOPY:Creates snapshot copy of the project. • EXPORTPROPERTYPLACEMENTSSCHEMAS:Exports property placements schemas. • IMPORTPROPERTYPLACEMENTSSCHEMAS:Imports property placements schemas. • REORGANIZE:Reorganizes project. • CORRECTPROJECTITEMS:Corrects project items. • LOADDIRECTORY: Scans directory for projects to add them into the project management. This type can be used as 'Stand-Alone' or with the Parameter: PROJECTSDIRECTORY and SCANSUBDIRECTORIES |
PROJECTNAME |
Project name with full path (optional). If not entered, the selected project is used when the action is call from GUI (like from a script or button bar). If called from the windows command line, PROJECTNAME must be set or the must be used first, otherwise an exception is thrown. |
FILENAME |
Full path / name of the XML file to be imported, or the filename to be send by e-mail, or full file path to be published to, or full file path to target project when creating snapshot copy. |
SCHEME |
Name of the scheme. This parameter is only effective with the following values of the TYPE parameter:PUBLISHTODISK, PUBLISHTOEMAIL, CREATESNAPSHOTCOPY, CORRECTPROJECTITEMS. |
OVERWRITE |
If the imported property placement schema already exists, this parameter specifies whether it should be overwritten. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:IMPORTPROPERTYPLACEMENTSSCHEMAS. |
EXTENDEDMODE |
Enables extended mode while reorganizing the project. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:REORGANIZE. |
PROJECTSDIRECTORY |
Path to directory which will be scanned. If null or empty then default path 'USER.TrDMProject.Masterdata.Pathnames.Projects' is used. |
SCANSUBDIRECTORIES |
Determines whether sub directories are also scanned for projects. Possible values: FALSE, TRUE (default) |
The specified project may be open or closed. If the project is not open, it is opened when the process is started and closed after the export.